PM1605BT electronic dosimeter is equipped with a Geiger-Mueller counter for extended measurement of the ambient dose equivalent and ambient dose equivalent rate. Instruments are able to search, detect and locate radioactive sources, alert the user with audible, visual and vibration alarms, transmit stored data to a PC or smartphone.
The dosimeter is designed to withstand extreme environmental conditions such as limited visibility, raised noise, high temperatures, exposure to sea water, shock and falls. Control panel with two big buttons allows the using of protective gloves while operating the instrument.
The instruments are recommended for personal radiation protection of first responders, HAZMAT teams, civil defense, firefighters and the other divisions who deal with radiological emergencies.
_PM1605_Leaflet (2023.04).pdf
Detector |
Geiger-Mueller tube |
Dose indication range |
0.01 µSv to 100 Sv |
Dose measurement range |
1 µSv to 100 Sv |
Dose measurement accuracy |
±15 % |
Dose rate indication range |
0.01 µSv/h to 13 Sv/h |
Dose rate measurement accuracy |
±(15 + 0.0015/Ḣ) % (where Ḣ is the measured dose rate in mSv/h) |
Energy range |
48 keV to 3 MeV |
Energy response relative to 0.662 MeV (137Cs) |
±30 % |
Water resistant |
1 m |
Power |
one alkaline AA battery, 1.5 V |
Alarms |
audible, visual, vibration |
Thresholds |
2 independent thresholds for both dose and dose rate |
Memory |
2000 events |
Smartphone communication |
Bluetooth 4.0 LE |
PC communication |
USB |
Battery lifetime |
9 months* *when the average dose rate is not more than 0.3 µSv/h; backlight and alarms are activated for not more than 20 s per 24 hours |
Ingress protection |
IP68 |
Drop test |
1.5 m |
Dimensions |
114 × 62 × 20 mm 114 × 62 × 36 mm (with clip) |
Weight |
250 g |
Operating temperature |
–30 °C to 65 °C |
Atmospheric pressure |
84 to 106.7 kPa |
Humidity |
98 % at 40 °С |
Mean service lifetime |
8 years |